772
YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
■
E3-12: Motor 2 Mid Point B Voltage
No.
(Hex.)
Name
Description
Default
(Range)
E3-12
(0346)
Expert
Motor 2 Mid Point B Voltage
Sets a middle output voltage for the motor 2 V/f pattern. Set this parameter to adjust the V/f pattern
for the constant output range. Usually it is not necessary to change this parameter.
0.0 V
(200 V Class: 0.0 to 255.0 V,
400 V Class: 0.0 to 510.0 V)
Note:
•
Set this parameter to
0.0
to disable the function.
•
When you initialize the drive, this parameter is reset to the default value.
•
The setting value changes automatically when you do Auto-Tuning (rotational and stationary 1 or 2).
■
E3-13: Motor 2 Base Voltage
No.
(Hex.)
Name
Description
Default
(Range)
E3-13
(0347)
Expert
Motor 2 Base Voltage
Sets the base voltage for the motor 2 V/f pattern. Set this parameter to adjust the V/f pattern for the
constant output range. Usually it is not necessary to change this parameter.
0.0 V
(200 V Class: 0.0 to 255.0 V,
400 V Class: 0.0 to 510.0 V)
Note:
•
When you initialize the drive, this parameter is reset to the default value.
•
The setting value changes automatically when you do Auto-Tuning (rotational and stationary 1 or 2).
◆
E4: Motor 2 Parameters
E4 parameters [Motor 2 Parameters]
set induction motor data. To switch drive operation from one motor to a
different motor, configure motor 2.
Auto-Tuning automatically sets the
E4 parameters
to the best values for the application. If you cannot do Auto-
Tuning, set the
E4 parameters
manually.
Note:
E3-xx
and
E4-xx
are available when
H1-xx = 16 [MFDI Function Select = Motor 2 Selection]
.
■
E4-01: Motor 2 Rated Current
No.
(Hex.)
Name
Description
Default
(Range)
E4-01
(0321)
Motor 2 Rated Current
Sets the motor rated current for motor 2 in amps.
Determined by o2-04, C6-01
(10% to 200% of the drive
rated current)
Note:
•
If
E4-01 ≤ E4-03 [Motor 2 Rated No-Load Current]
, the drive will detect
oPE02 [Parameter Range Setting Error]
will be detected.
•
The default settings and setting ranges are in these units:
–
0.01 A: 2004 to 2042, 4002 to 4023
–
0.1 A: 2056 to 2415, 4031 to 4720
The value set for
E4-01
becomes the reference value for motor protection, the torque limit, and torque control. Enter
the motor rated current written on the motor nameplate. Auto-Tuning automatically sets the value of
E4-01
to the
value input for [Motor Rated Current].
■
E4-02: Motor 2 Rated Slip
No.
(Hex.)
Name
Description
Default
(Range)
E4-02
(0322)
Motor 2 Rated Slip
Sets the motor rated slip for motor 2.
Determined by o2-04, C6-01
(0.000 - 20.000 Hz)
The value set in
E4-02
becomes the base slip compensation value. The drive sets this parameter during Rotational
Auto-Tuning and Stationary Auto-Tuning. If you cannot do Auto-Tuning, use the information written on the motor
nameplate and this formula to calculate the motor rated slip:
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...