11.22 Parameters Changed by PM Motor Code Selection
634
YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
No.
Name
Unit
Motor Code (setting value of E5-01)
E5-24
PM Back-EMF L-L
Vrms (mV/rpm)
mV/min
-1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
E1-04
Maximum Output
Frequency
Hz
57.5
57.5
57.5
57.5
57.5
57.5
57.5
57.5
E1-05
Maximum Output
Voltage
V
190.0
190.0
190.0
190.0
190.0
190.0
190.0
190.0
E1-06
Base Frequency
Hz
57.5
57.5
57.5
57.5
57.5
57.5
57.5
57.5
E1-09
Minimum Output
Frequency
Hz
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
C5-17
Motor Inertia
kgm
2
0.0022
0.0042
0.0081
0.0133
0.0168
0.027
0.044
0.054
L3-24
Motor Accel Time @
Rated Torque
s
0.080
0.081
0.078
0.088
0.066
0.070
0.085
0.071
n5-02
Motor Inertia
Acceleration Time
s
0.080
0.081
0.078
0.088
0.066
0.070
0.085
0.071
n8-49
Heavy Load Id Current
%
-8.4
-11.0
-10.7
-10.7
-9.4
-22.5
-22.2
-16.7
*1
The default setting changes when the setting for
o2-04 [Drive Model Selection]
changes.
Table 11.32 SST4 Series Motor Code Setting for Specification of 200 V at 1150 min
-1
(r/min)
No.
Name
Unit
Motor Code (setting value of E5-01)
E5-01
PM Motor Code
Selection
-
240E
240F
2410
2412
2413
2414
2415
2416
Voltage Class
V
200
200
200
200
200
200
200
200
Capacity
kW
15
18
22
30
37
45
55
75
Motor Rotation Speed
min
-1
1150
1150
1150
1150
1150
1150
1150
1150
E5-02
PM Motor Rated Power
kW
15
18.50
22.00
30.00
37.00
45.00
55.00
75.00
E5-03
PM Motor Rated Current
(FLA)
A
55.9
65.4
77.0
103.5
126.0
153.1
188.5
260.4
E5-04
PM Motor Pole Count
-
6
6
6
6
6
6
6
6
E5-05
PM Motor Resistance
(ohms/phase)
Ω
0.083
0.065
0.052
0.035
0.026
0.019
0.013
0.009
E5-06
PM d-axis Inductance
(mH/phase)
mH
3.50
2.92
2.55
2.03
1.59
1.24
0.98
0.70
E5-07
PM q-axis Inductance
(mH/phase)
mH
4.23
3.79
3.22
2.46
1.92
1.64
1.37
0.97
E5-09
PM Back-EMF Vpeak
(mV/(rad/s))
mVs/rad
364.5
404.5
445.1
444.4
447.3
470.8
422.4
418.3
E5-24
PM Back-EMF L-L
Vrms (mV/rpm)
mV/min
-1
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
E1-04
Maximum Output
Frequency
Hz
57.5
57.5
57.5
57.5
57.5
57.5
57.5
57.5
E1-05
Maximum Output
Voltage
V
190.0
190.0
190.0
190.0
190.0
190.0
190.0
190.0
E1-06
Base Frequency
Hz
57.5
57.5
57.5
57.5
57.5
57.5
57.5
57.5
E1-09
Minimum Output
Frequency
Hz
2.9
2.9
2.9
2.9
2.9
2.9
2.9
2.9
C5-17
Motor Inertia
kgm
2
0.063
0.113
0.137
0.252
0.304
0.410
0.55
0.82
L3-24
Motor Accel Time @
Rated Torque
s
0.061
0.089
0.090
0.122
0.119
0.132
0.145
0.159
n5-02
Motor Inertia
Acceleration Time
s
0.061
0.089
0.090
0.122
0.119
0.132
0.145
0.159
n8-49
Heavy Load Id Current
%
-13.7
-15.2
-10.9
-9.8
-9.3
-11.5
-17.7
-17.1
*1
The default setting changes when the setting for
o2-04 [Drive Model Selection]
changes.
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...