Procedure
Configuration Parameter
Task Contents
1
Reference 1
1.
Set
b1-01 = 1 [Frequency Reference Selection 1 = Analog Input]
.
2.
Set
H3-02 = 0 [Terminal A1 Function Selection = Frequency Reference]
.
3.
Set
H3-01 = 1 [Terminal A1 Signal Level Select = -10 to +10V (Bipolar Reference)]
.
2
Reference 2
1.
Set
H3-06 = 2 [Terminal A3 Function Selection = Auxiliary Frequency Reference 1]
.
2.
Set
H3-05 = 1 [Terminal A3 Signal Level Select = -10 to +10V (Bipolar Reference)]
.
3
Signal type of analog input
Set DIP switches S1-1 and S1-3 on the control circuit board to the V-side (voltage).
Note:
Set this before you energize the drive.
4
Reference 3
Set the value of
d1-03 [Reference 3]
.
5
Reference 4
Set the value of
d1-04 [Reference 4]
.
6
Reference 5
Set the value of
d1-05 [Reference 5]
.
7
Jog Reference
Set
d1-17 [Jog Reference]
to the jog speed.
8
External digital input (3
inputs)
Set the
Multi-Step Speed Reference 1 to 3 [H1-xx = 3, 4, 5]
to one of the MFDI terminals S1 to S8.
9
JOG command
Set the
Jog Reference Selection [H1-xx = 6]
to one of the MFDI terminals S1 to S8.
Use the Maximum 17-Step Speed with All Digital Inputs
This section is the procedure to set the 17-step speeds (17 types of frequency references) without an analog input.
Procedure
Configuration Parameter
Task Contents
1
Reference 1
1.
Set
b1-01 = 0 [Frequency Reference Selection 1 = Keypad]
.
2.
Set the value of
d1-01 [Reference 1]
.
2
Reference 2
1.
Set
H3-06 = F [Terminal A3 Function Selection = Not Used]
, and disables the analog reference.
2.
Set the value of
d1-02 [Reference 2]
.
3
Reference 3
1.
Set
H3-10 = F [Terminal A2 Function Selection = Not Used]
, and disables the analog reference.
2.
Set the value of
d1-03 [Reference 3]
.
4
Reference 4
Set the value of
d1-04 [Reference 4]
.
5
Reference 5 to 16
Sets the values of
d1-05 to d1-16 [Reference 5 to 16]
.
6
Jog Reference
Set
d1-17 [Jog Reference]
to the jog speed.
7
External digital input (4
inputs)
Set
Multi-Step Speed Reference 1 to 4 [H1-xx = 3, 4, 5, 32]
to one of the MFDI terminals S1 to S8.
8
JOG command
Set the
Jog Reference Selection [H1-xx = 6]
to one of the MFDI terminals S1 to S8.
Multi-step Speed Operation Combinations
Refer to
and
for information about multi-step speed reference combinations. The selected
frequency reference changes when the combination of digital input signals from an external source changes.
Table 12.37 Multi-step Speed Reference and MFDI Terminal Combinations
Related Parameters
Multi-Step Speed
Reference 1
H1-xx = 3
Multi-Step Speed
Reference 2
H1-xx = 4
Multi-Step Speed
Reference 3
H1-xx = 5
Multi-Step Speed
Reference 4
H1-xx = 32
Jog Reference
H1-xx = 6
Reference 1 (set in
b1-01
)
OFF
OFF
OFF
OFF
OFF
Reference 2 (
d1-02
or
terminals A1, A2, A3)
ON
OFF
OFF
OFF
OFF
Reference 3 (
d1-03
or
terminals A1, A2, A3)
OFF
ON
OFF
OFF
OFF
Reference 4 (
d1-04
)
ON
ON
OFF
OFF
OFF
Reference 5 (
d1-05
)
OFF
OFF
ON
OFF
OFF
Reference 6 (
d1-06
)
ON
OFF
ON
OFF
OFF
Reference 7 (
d1-07
)
OFF
ON
ON
OFF
OFF
Reference 8 (
d1-08
)
ON
ON
ON
OFF
OFF
Reference 9 (
d1-09
)
OFF
OFF
OFF
ON
OFF
Reference 10 (
d1-10
)
ON
OFF
OFF
ON
OFF
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...