YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
225
Model
Terminal
Recommended
Gauge
mm
2
Applicable Gauge
(IP20 Applicable
)
mm
2
Wire Stripping
mm
Terminal Screw
Tightening Torque
N
∙
m (in
∙
lb)
Size
Shape
4477
R/L1, S/L2, T/L3
120 × 4P
70 - 150 × 4P
(150 × 4P)
-
M12
Hex self-locking nut
35
(310)
U/T1, V/T2, W/T3
95 × 4P
70 - 150 × 4P
(120 - 150 × 4P)
-
M12
Hex self-locking nut
35
(310)
-, +1
95 × 4P
95 - 185 × 4P
(185 × 4P)
-
M12
Hex self-locking nut
35
(310)
+3
70 × 4P
35 - 95 × 4P
(95 × 4P)
-
M12
Hex self-locking nut
35
(310)
150
50 - 150
(-)
-
M12
Hex bolt (slotted)
32 - 40
(283 - 354)
4568
R/L1, S/L2, T/L3
120 × 4P
70 - 150 × 4P
(150 × 4P)
-
M12
Hex self-locking nut
35
(310)
U/T1, V/T2, W/T3
95 × 4P
70 - 150 × 4P
(120 - 150 × 4P)
-
M12
Hex self-locking nut
35
(310)
-, +1
95 × 4P
95 - 185 × 4P
(185 × 4P)
-
M12
Hex self-locking nut
35
(310)
+3
70 × 4P
35 - 95 × 4P
(95 × 4P)
-
M12
Hex self-locking nut
35
(310)
95 × 2P
60 - 150
(-)
-
M12
Hex bolt (slotted)
32 - 40
(283 - 354)
4605
R/L1, S/L2, T/L3
120 × 4P
70 - 150 × 4P
(150 × 4P)
-
M12
Hex self-locking nut
35
(310)
U/T1, V/T2, W/T3
95 × 4P
70 - 150 × 4P
(120 - 150 × 4P)
-
M12
Hex self-locking nut
35
(310)
-, +1
95 × 4P
95 - 185 × 4P
(185 × 4P)
-
M12
Hex self-locking nut
35
(310)
+3
70 × 4P
35 - 95 × 4P
(95 × 4P)
-
M12
Hex self-locking nut
35
(310)
95 × 2P
60 - 150
(-)
-
M12
Hex bolt (slotted)
32 - 40
(283 - 354)
4720
R/L1, S/L2, T/L3
120 × 4P
70 - 150 × 4P
(150 × 4P)
-
M12
Hex self-locking nut
35
(310)
U/T1, V/T2, W/T3
95 × 4P
70 - 150 × 4P
(120 - 150 × 4P)
-
M12
Hex self-locking nut
35
(310)
-, +1
95 × 4P
95 - 185 × 4P
(185 × 4P)
-
M12
Hex self-locking nut
35
(310)
+3
70 × 4P
35 - 95 × 4P
(95 × 4P)
-
M12
Hex self-locking nut
35
(310)
95 × 2P
60 - 150
(-)
-
M12
Hex bolt (slotted)
32 - 40
(283 - 354)
*1
For IP20 protection, use wires that are in the range of applicable gauges.
*2
Remove insulation from the ends of wires to expose the length of wire shown.
*3
For wire gauges more than 30 mm
2
, tighten to a tightening torque of 4.1 N∙m to 4.5 N∙m (36 in∙lb to 40 in∙lb).
*4
Install a GFCI with this wire gauge to maintain compliance with IEC/EN 61800-5-1:2007.
*5
Terminals - and +1 have two screws. The Recommended Gauge is the wire gauge for one terminal.
*6
A junction terminal is necessary to connect a braking resistor unit (LKEB-series) to terminals B1 and B2.
■
Connect a Fuse to the Input Side (Primary Side)
The drive circuit protection must comply with IEC/EN 61800-5-1:2007 for protection against a short circuit in the
internal circuitry. Yaskawa recommends connecting semiconductor protection fuses on the input side for branch
circuit protection.
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...