YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
997
12.12 T: Auto-Tuning
Numbers identifying the
T parameters
are displayed when an LED keypad is used. The names of the parameters are
displayed on the LCD screen of the LCD keypad. Set the following.
•
Induction Motor Auto-Tuning
•
PM Motor Auto-Tuning
•
ASR and Inertia Tuning
◆
T0: Tuning Mode Selection
■
T0-00: Tuning Mode Selection
When your control method supports Control Tuning, set
T0-00
first. Then, set
T1-00 [Motor 1/Motor 2 Selection]
to
select the motor you will tune. Then, set the tuning mode in
T2-01 [PM Auto-Tuning Selection]
or
T3-00 [Control
Loop Tuning Selection]
.
No.
(Hex.)
Name
Description
Default
(Range)
T0-00
(1197)
Tuning Mode Selection
Sets the type of Auto-Tuning.
0
(0, 1)
0 : Motor Parameter Tuning
1 : Control Tuning
Note:
The available tuning modes are different for different control methods.
◆
T1: Induction Motor Auto-Tuning
T1 parameters
set the Auto-Tuning input data for induction motor tuning.
Note:
•
The base frequency of drive dedicated motors and special motors for use with vector control may be lower than the base frequency of
general-purpose motors, which is 50 Hz or 60 Hz. In such cases, this lower frequency is used as the value for
E1-06 [Base Frequency]
and
E1-04 [Maximum Output Frequency]
after Auto-Tuning completes. If the maximum output frequency is too low and causes problems,
change the setting of
E1-04
after Auto-Tuning completes.
•
The following induction motor parameters are set automatically.
–
E1-xx [V/f Pattern for Motor 1]
–
E2-xx [Motor Parameters]
–
E3-xx [V/f Pattern for Motor 2]
–
E4-xx [Motor 2 Parameters]
–
F1-xx [Encoder Options]
(only with Closed Loop Vector Control)
■
T1-00: Motor 1/Motor 2 Selection
No.
(Hex.)
Name
Description
Default
(Range)
T1-00
(0700)
Motor 1/Motor 2 Selection
Sets which motor to tune when motor 1/2 switching is enabled.
1
(1, 2)
Note:
This parameter is available when
H1-xx = 16 [Motor 2 Selection]
. The keypad will not show this parameter when
H1-xx ≠ 16
.
1 : Motor 1 (sets E1-xx, E2-xx)
Auto-Tuning automatically sets parameters
E1-xx
and
E2-xx
for motor 1.
2 : Motor 2 (sets E3-xx, E4-xx)
Auto-Tuning automatically sets parameters
E3-xx
and
E4-xx
for motor 2. Make sure that you connect motor 2 to the
drive for Auto-Tuning.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...