YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
999
■
T1-06: Number of Motor Poles
No.
(Hex.)
Name
Description
Default
(Range)
T1-06
(0706)
Number of Motor Poles
Sets the number of motor poles.
4
(2 to 120)
■
T1-07: Motor Base Speed
No.
(Hex.)
Name
Description
Default
(Range)
T1-07
(0707)
Motor Base Speed
Sets the motor base speed for Auto-Tuning (min
-1
(r/min)).
1750 min
-1
(r/min)
(0 - 35400 min
-1
(r/min))
■
T1-08: Encoder Pulse Count (PPR)
No.
(Hex.)
Name
Description
Default
(Range)
T1-08
(0708)
Encoder Pulse Count (PPR)
Sets the number of PG (pulse generator, encoder) pulses.
1024 ppr
(0 - 60,000 ppr)
Set the actual number of pulses for one full motor rotation.
■
T1-09: Motor No-Load Current
No.
(Hex.)
Name
Description
Default
(Range)
T1-09
(0709)
Motor No-Load Current
Sets the no-load current of the motor.
-
(0A - T1-04; max. of 2999.9)
Note:
The display units are different for different models:
•
2004 to 2042, 4002 to 4023: 0.01 A
•
2056 to 2415, 4031 to 4720: 0.1 A
The value shown is the no-load current that is automatically calculated from the values set in
T1-02 [Motor Rated
Power]
and
T1-04 [Motor Rated Current]
. Set the no-load current shown on the motor test report. If the motor test
report is not available, do not change this parameter.
■
T1-10: Motor Rated Slip Frequency
No.
(Hex.)
Name
Description
Default
(Range)
T1-10
(070A)
Motor Rated Slip Frequency
Sets motor rated slip.
-
(0.000 - 20.000 Hz)
Shows 0.000 Hz as the default value. Set the rated slip shown on the motor test report. If the motor test report is not
available, do not change this parameter.
■
T1-11: Motor Iron Loss
No.
(Hex.)
Name
Description
Default
(Range)
T1-11
(070B)
Motor Iron Loss
Sets the iron loss for calculating the energy-saving coefficient.
Determined by E2-11 or E4-
11
(0 - 65535 W)
Note:
The default setting is different for different motor codes and motor parameter settings.
The value shown is the
E2-10 [Motor Iron Loss]
or
E4-10 [Motor 2 Iron Loss]
for the motor output set in
T1-02
[Motor Rated Power]
. If the motor test report is available, enter the motor iron loss value to
T1-11
.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...