YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
253
Drive Model
Fuse
Manufacturer: Bussmann
Model
Quantity
4089
FWP-300A
2
4103
4140
FWP-350A
2
4168
FWP-450A
2
4208
FWP-600A
2
4250
FWP-700A
2
4302
FWP-800A
2
4371
Not applicable
4414
4477
4568
4605
4720
◆
Low Voltage Wiring for Control Circuit Terminals
You must provide low voltage wiring as specified by the National Electric Code (NEC), the Canadian Electric Code,
Part I (CEC), and local codes. Yaskawa recommends the NEC class 1 circuit conductor. Use the UL approved class 2
power supply for external power supply.
Table 5.17 Control Circuit Terminal Power Supplies
Input/Output
Terminals
Power Supply Specifications
Digital input
S1 to S8, SN, SC, SP
Uses the LVLC power supply in the drive.
Use the UL Listed class 2 power supply for external power
supply.
Analog input
A1 to A3, AC, +V, -V
Uses the LVLC power supply in the drive.
Use the UL Listed class 2 power supply for external power
supply.
Analog output
FM, AM, AC
Uses the LVLC power supply in the drive.
Pulse train output
MP, AC
Uses the LVLC power supply in the drive.
Use the UL Listed class 2 power supply for external power
supply.
Pulse train input
RP, AC
Uses the LVLC power supply in the drive.
Use the UL Listed class 2 power supply for external power
supply.
Safe disable input
H1, H2, HC
Uses the LVLC power supply in the drive.
Use the UL Listed class 2 power supply for external power
supply.
Serial communication input/output
D+, D-, AC
Uses the LVLC power supply in the drive.
Use the UL Listed class 2 power supply for external power
supply.
24 V external power supply
PS, AC
Use the UL Listed class 2 power supply.
◆
Drive Motor Overload and Overheat Protection
The drive motor overload and overheat protection function complies with the National Electric Code (NEC) and the
Canadian Electric Code, Part I (CEC).
Set the Motor Rated Current and
L1-01 through L1-04 [Motor Overload Protection Select]
correctly to enable motor
overload and overheat protection.
Refer to the control method and set the motor rated current with
E2-01 [Motor Rated Current (FLA)]
,
E5-03 [PM
Motor Rated Current (FLA)]
, or
E9-06 [Motor Rated Current (FLA)]
.
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...