8.4 Replace Cooling Fans and Circulation Fans
404
YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
3.
Put the cables in their initial locations.
Note:
Safety the relay cable to the hook.
A - Cooling fan
B - Cable hook
C - Relay connector
D - Circulation fan
4.
Put the fan unit back into its initial position.
5.
Slide the fan unit to the right and safety it with mounting screws.
Tighten the screws to a tightening torque of 1.96 N
∙
m to 2.53 N
∙
m (17.35 lb.
∙
in to 22.39 lb.
∙
in).