756
YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
■
d5-04: Speed Limit
No.
(Hex.)
Name
Description
Default
(Range)
d5-04
(029D)
Speed Limit
Sets the speed limit during Torque Control as a percentage of
E1-04 [Maximum Output Frequency]
.
Set
d5-03 = 2 [Speed Limit Selection = d5-04 Setting]
before you set this parameter.
0%
(-120 - +120%)
The speed limit is a positive value when it is in the same direction as the Run command. The speed limit is a negative
value when it is in the opposite direction of the Run command.
■
d5-05: Speed Limit Bias
No.
(Hex.)
Name
Description
Default
(Range)
d5-05
(029E)
Speed Limit Bias
Sets the speed limit bias value as a percentage of
E1-04 [Maximum Output Frequency]
.
10%
(0 - 120%)
Adjusts the margin for the speed limit.
■
d5-06: Speed/Torque Changeover Time
No.
(Hex.)
Name
Description
Default
(Range)
d5-06
(029F)
Speed/Torque Changeover
Time
Sets the delay time to switch between Speed Control and Torque Control. Set
H1-xx = 71 [MFDI
Function Selection = Torque Control]
before you set this parameter.
0 ms
(0 - 1000 ms)
The analog input (torque reference, speed limit value) holds at the value when the drive switched between Speed and
Torque Control in the time of the Speed/Torque Changeover Timer. During this time, prepare to switch to an external
source.
■
d5-08: Uni-directional Speed Limit Bias
No.
(Hex.)
Name
Description
Default
(Range)
d5-08
(02B5)
Uni-directional Speed Limit
Bias
Sets the direction of the speed limit reference to which Speed Limit Bias
[d5-05]
applies.
1
(0, 1)
0 : Disabled
The drive applies the speed limit bias in the speed limit direction and the opposite direction.
1 : Enabled
The drive applies the speed limit bias in the opposite direction of the speed limit only.
◆
d6: Field Weakening /Forcing
d6 parameters
set the field weakening and field forcing functions.
The field weakening function decreases the energy consumption of the motor. It decreases the output voltage of the
drive to a set level. The function decreases the motor excitation current inversely proportional to speed in a constant
output range, and does not let the induced voltage of the motor become more than the power supply voltage. To
enable this function, set
Field Weakening [H1-xx = 63]
ON.
Note:
Use the Field Weakening function in constant light-load applications. To control the energy consumption of the motor for other load
conditions, use the
b8 parameters [Energy Saving]
.
The Field Forcing function adjusts the delaying influence of the motor time constant when the drive changes the
excitation current reference and it also increases motor responsiveness. This function uses a high motor excitation
current reference for drive start-up only to help develop actual motor excitation current. Enable the Field Forcing
function to increase motor responsiveness.
Note:
You cannot use Field Forcing during DC Injection Braking.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM
EZOLV
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...