4.10 Fine Tuning during Test Runs (Adjust the Control Function)
202
YASKAWA
SIEPC71061737B GA800 Drive Technical Reference
4.10
Fine Tuning during Test Runs (Adjust the Control
Function)
This section gives information about the adjustment procedures to stop hunting or oscillation errors caused by control
function during a test run. Adjust the applicable parameters as specified by your control method and drive status.
•
V/f Control and Closed Loop V/f Control on page 202
•
Open Loop Vector Control Method on page 203
•
Closed Loop Vector Control Method on page 204
•
Advanced Open Loop Vector Control Method on page 205
•
Fine-Tuning Open Loop Vector Control for PM Motors on page 206
•
Advanced Open Loop Vector Control Method for PM on page 207
•
Closed Loop Vector Control Method for PM on page 207
•
EZ Open Loop Vector Control Method on page 208
Note:
This section only lists frequently adjusted parameters. If you must adjust parameters that have a higher degree of precision, contact Yaskawa.
◆
V/f Control and Closed Loop V/f Control
Table 4.17 Parameters for Fine Tuning the Drive (V/f and CL-V/f)
Issue
Parameter Number
Possible Solutions
Default
Recommended Setting
Hunting or oscillation at mid-range
speeds (10 Hz to 40 Hz)
n1-02 [Hunting Prevention Gain
Setting]
•
If torque is not sufficient with
heavy loads, decrease the
setting value.
•
If hunting or oscillation occur
with light loads, increase the
setting value.
•
If hunting occurs with a low-
inductance motor, for example a
motor with a larger frame size
or a high-frequency motor,
lower the setting value.
1.00
0.10 - 2.00
•
The volume of the motor
excitation sound is too high.
•
Hunting or oscillation at low
speeds (10 Hz or lower), or at
mid-range speeds (10 Hz to 40
Hz)
C6-02 [Carrier Frequency
Selection]
•
If the volume of the motor
excitation sound is too high,
increase the carrier frequency.
•
If hunting or oscillation occur at
low or mid-range speeds,
decrease the carrier frequency.
1 (2 kHz)
1 to upper limit value
•
Unsatisfactory motor torque
and speed response
•
Hunting or oscillation
C4-02 [Torque Compensation
Delay Time]
•
If torque or speed response are
slow, decrease the setting value.
•
If hunting or oscillation occur,
increase the setting value.
200 ms
100 ms to 1000 ms
•
Torque at low speeds (10 Hz or
lower) is not sufficient.
•
Hunting or oscillation
C4-01 [Torque Compensation
Gain]
•
If torque at low speeds (10 Hz
or lower) is not sufficient,
increase the setting value.
•
If hunting or oscillation occur
with light loads, decrease the
setting value.
1.00
0.50 - 1.50
•
Torque at low speeds (10 Hz or
lower) is not sufficient.
•
Large initial vibration at start
up.
•
E1-08 [Mid Point A Voltage]
•
E1-10 [Minimum Output
Voltage]
•
If torque at low speeds (10 Hz
or lower) is not sufficient,
increase the setting value.
•
If there is large initial vibration
at start up, decrease the setting
value
•
E1-08: 15.0 V
•
E1-10: 9.0 V
Default s/- 5 V
Speed precision is unsatisfactory.
(V/f Control)
C3-01 [Slip Compensation Gain]
Set
E2-01 [Motor Rated Current],
E2-02 [Motor Rated Slip], and E2-
03 [Motor No-Load Current]
, then
adjust
C3-01
.
0.0 (no slip compensation)
0.5 - 1.5
Speed precision is unsatisfactory.
(Closed Loop V/f Control)
•
C5-01 [ASR Proportional Gain
1]
•
C5-02 [ASR Integral Time 1
(I)]
Adjust
C5-01, C5-02.
•
C5-01: 0.20
•
C5-02: 0.200 s
•
Proportional gain = 0.10 to 1.00
•
Integral time = 0.100 to 2.000 s
*1
The default setting changes when the settings for
C6-01 [Normal / Heavy Duty Selection]
and
o2-04 [Drive Model (KVA) Selection]
change.
*2
The default setting changes when the settings for
A1-02 [Control Method Selection]
and
o2-04 [Drive Model (KVA) Selection]
change.
*3
The default setting changes when the settings for
A1-02 [Control Method Selection]
and
E1-03 [V/f Pattern Selection]
change.
Содержание GA800 Series
Страница 2: ...This Page Intentionally Blank 2 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 20: ...i 3 Warranty Information 20 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 30: ...1 3 Features and Advantages of Control Methods 30 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 58: ...2 9 Installation Methods 58 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 144: ...4 4 Start up Procedures 144 YASKAWA SIEPC71061737B GA800 Drive Technical Reference Figure 4 8 Basic Steps before Startup...
Страница 268: ...5 6 Safe Disable Input 268 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 306: ...6 3 MEMOBUS Modbus Communications 306 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 370: ...7 10 Troubleshooting Without Fault Display 370 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...
Страница 426: ...8 7 Storage Guidelines 426 YASKAWA SIEPC71061737B GA800 Drive Technical Reference...