appendix1‑24
112
Scaling data ratio denominator (on the command unit)
Specifies the scale factor denominator to convert the units of axis related parameters in pulses to
user definable units (axis command units). The value specified is equivalent to the axis scaling data
(on the pulse) parameter. If the rotary coordinate system is selected, this parameter is set to the
number of units in one rotation of the axis command coordinate system. For example,
Ex) Rotation: Circumference [micron]
Linear: Ball screw lead pitch [micron]
Pulse units=(#113 / #112) * axis command units
10000
99999999
depend on motor.driver type
Min:
Max:
Initial:
Unit:
Axis command unit
Initial value:
[rotation] 360000 [unit/rev]
[Linear] 1000000 [unit/m]
ScaleUnit
Updated on power cycle
Dec
113
Scaling data ratio numerator (on the pulse)
Specifies the scale factor numerator to convert the units of axis related parameters to user definable
units (axis command units). The value specified is equivalent to the axis scaling data (on the
command unit) parameter. If the rotary coordinate system is selected, the parameter value is set to
the number of pulses in one rotation of the pulse coordinate system.
Pulse units = (#113 / #112) * axis command units
10000
99999999
depend on motor.driver type
Min:
Max:
Initial:
Unit:
pulse
Initial value: Motor resolution [rotation] unit [pls/rev]
[linear] unit [pls/m]
ScalePulse
Updated on power cycle
Dec
115
Length of encoder/resolver cables
Specifies the length of encoder and resolver cables.
0
100
0
Min:
Max:
Initial:
Unit:
m
Only for ABS type
Cbl̲Length
Updated on power cycle
Dec
116
Absolute linear coordinate limit #1
This is a value used to determine the coordinate value when AC power is turned on if the linear
coordinate system is selected in a motor with absolute encoder/resolver. The processing is performed
in combination with absolute linear coordinate limit value #2.
‑99999999
99999999
depend on motor.driver type
Min:
Max:
Initial:
Unit:
Axis command unit
Only for ABS type
Initial value:
[rotation]: 179999 [unit/rev]
[Linear] : 499999 [unit/m]
ABS̲L̲Lmt1
Updated on power cycle
Dec
TI 71M01D06‑01E 2nd Edition : 2007.01.10‑00