6.10.1 Version V1.50 - Additional Function
In this section, specifications added from V1.50 of firmware for DrvP
Ⅲ
are outlined. All of
functions below are upper level compatible since these are using reserved storage and
mounted. DYNASERV and LINEARSERV driven with DrvP
Ⅲ
having older firmware version
is possible to be drive with the version V1.50 also.
(1) Additional Function for Software I/O
Register Parameter Select” and “Software Reboot” functions are added to Software I/O
signals. These are not configured with hardware I/O at default setting. Configure the software
I/O through software when using.
Refer to “Chapter 6: I/O Contact Signals” for configuration.
Title block
bit
Functions
Register
Parameter
Select
IN_EEPROM_SEL
5 5
[Register] or [Set] is selectable at sequence
of parameter writing. Value can be wrote to
nonvolatility memory by selecting [Register].
Software
Reboot
IN_REBOOT 0
7
Drive is rebooted from controller by detecting
rising edge of the signal.
Processing Sequence
1) Register Parameter Select
2) Software Reboot
IN_PRM_WR_REQ
IN_WR_PRM_NO
IN_WR_PRM_DATA
No inquiry
No inquiry
No inquiry
No inquiry
ON
OFF
ON
OUT_PRM_WR_END
OUT_PRM_WR_OK
OFF
ON
OFF
If wrote properly ON
If not wrote properly OFF
IN_EEPROM_SEL
No inquiry
No inquiry
IN_REBOOT
ON
OFF
Over 20ms