6-25
TI71M01D06-01EN 3rd Edition: 2012.12.01
(1) How to Select Operation Privilege
The main operation privilege is always set to the controller interface when the power is turned
ON.
[1]
There are three ways to switch the main operation privilege from the controller
interface side to the serial communication side.
Method 1: It can be switched when opening the Operation window in the utility
software.
Method 2: It can be switched by the switch button in the Operation window.
Method 3: It can be switched by issuing the command @5:0 from the terminal window.
[2]
There are two ways to switch the operation privilege from the RS communication side
to the controller interface side.
Method 1: It can be switched by the switch button in the Operation window in the utility
software.
Method 2: It can be switched by issuing the command @5:1 from the terminal window.
When opening the Operation window from the utility software, a message box asking whether
or not to select the serial communication side appears if the main operation privilege is on the
controller side.
Note that the main operation privilege is not returned to the original setting automatically
when the Operation window is closed. Make sure to switch the privilege back to the controller
interface if it is necessary to continue operating the system via the controller interface.
CAUTION