8-31
TI71M01D06-01EN 3rd Edition: 2012.12.01
8.6 Details of the Data Management Group Function
This section mainly describes the Data Management group that has the function of setting
and changing internal drive data.
8.6.1 #parameters
A character string command from [Terminal] can also be used to set #parameters in the drive.
However, in such a case, it is necessary to identify which #parameter of the function
corresponds to which number.
The #parameter function provides #parameter Setting window that is classified by purpose
and function. Therefore, #parameters for desired purposes can easily be set up.
Registering the Parameter Setting Window
Although each parameter of system setup registers 1 to 3 and error processing setup
registers 1 and 2 is managed in 32-bit length, it has assigned a unique definition in units of
bits internally. It is possible to perform similar settings from [Terminal]; however, settings can
be made easily by using this setting window.
The utility software may issue a software reset to the drive in order to reflect changes when
[Regist] is executed. As the servo is set to OFF during a reset operation, be sure to check
safety before operating.
Select a register to be set
Regist: Sets up the parameters in RAM
and EEPROM. The settings are
retained even if the power is OFF.
This display changes for each selected register. After
changing required items, execute [Save] or [Regist].
!
DANGER