appendix1‑19
95
Coin window #5
Specifies the coin window #5 width to be used for position settling check and coin standby in the
position control section.
0
9999999
5
Min:
Max:
Initial:
Unit:
Axis command unit or pulse
CoinWidth5
Dec
96
Coin window #6
Specifies the coin window #6 width to be used for position settling check and coin standby in the
position control section.
0
9999999
5
Min:
Max:
Initial:
Unit:
Axis command unit or pulse
CoinWidth6
Dec
97
Coin window #7
Specifies the coin window #7 width to be used for position settling check and coin standby in the
position control section.
0
9999999
5
Min:
Max:
Initial:
Unit:
Axis command unit or pulse
CoinWidth7
Dec
98
System setup register 2
Bit23 Enable actual position value filter
Bit21 Enable velocity feedback filter
Bit18 Enable first lag compensation filter
Bit17 Enable notch filter #2
Bit16 Enable notch filter #1
Bit 1 Disable M‑function when an error occurs
Bit 0 Enable start up operation (motion control table operation)
−
−
depend on motor.driver type
Min:
Max:
Initial:
Unit:
Initial value: H00030002
Enable actual position value filter [without interpolation process]: 0 Disable
[with interpoloation process] : 1 Enable
Enable velocity feedback filter : 0 Disable
Enable first lag compensation filter : 0 Disable
Enable notch filter #2 : 1 Enable
Enable notch filter #1 : 1 Enable
Disable M‑function when an error occurs : 1 Enable
Enable start up operation (motion control table operation) : 0 Disable
SystemReg2
Hex
TI 71M01D06‑01E 2nd Edition : 2007.01.10‑00