6-118
TI71M01D06-01EN 3rd Edition: 2012.12.01
IN_PRM_RD_REQ
IN_RD_PRM_NO
OUT_RD_PRM_DATA(High
、
Low)
ON
OFF
ON
OUT_PRM_RD_END
OUT_PRM_RD_OK
OFF
ON
OFF
#parameter/#monitor Read Function
The #parameter/#monitor read function operates regardless of the operating mode.
The CC-Link master station turns ON the IN_PRM_RD_REQ signal after setting the
#parameter/#monitor number to be read into the IN_RD_PRM_NO signal. The drive performs
#parameter/#monitor read processing, turns ON the OUT_PRM_RD_END signal, and notifies
that the processing has been complete. If the read processing completed normally, the drive
turns ON the OUT_PRM_RD_END signal, sets the data it read in the OUT_RD_PRM_DATA
(High, Low) signal, and turns ON the OUT_PRM_RD_OK signal. If the read processing did
not complete normally, the OUT_PRM_RD_OK signal stays OFF and the
OUT_RD_PRM_DATA (High, Low) is set to 0 when the drive turns ON the
OUT_PRM_RD_END signal.
IN_PRM_RD_REQ
IN_RD_PRM_NO
OUT_RD_PRM_DATA(High
、
Low)
ON
OFF
ON
OUT_PRM_RD_END
OUT_PRM_RD_OK
OFF
ON
OFF
No inquiry
Undefined
When write processing completed normally: ON
When write processing did not complete normally: OFF
No inquiry
Undefined
No inquiry
Undefined
When write processing completed normally: ON
When write processing did not complete normally: OFF
No inquiry
Undefined