8-38
TI71M01D06-01EN 3rd Edition: 2012.12.01
Logic I/O Initial Value Setting Window
The initial status of logic I/O at startup can be predetermined for each bit. For example, in the
case of an application you want to turn the servo ON unconditionally at power on, you can do
so after the power is turned ON by setting the applicable bit to ON when setting up logic I/O
initial value, instead of assigning [Servo ON command] to hard I/O. This will save some hard
I/O points.
The utility software issues a software reset to the drive in order to reflect settings after
executing [Regist]. The drive is set to the servo OFF state during a reset operation. Therefore,
be sure to check safety before operating.
Select logic I/O initial value setting.
Initial value setting is set to valid only for input bits.
Up to 16 bits can be displayed at a time. If there are more
than 16 bits, switch using this combo box, and register for
each page.
For bits with a check mark, initial values are set to ON.
A blank bit is a reserved bit, and thus not setting is allowed
!
DANGER