6-90
TI71M01D06-01EN 3rd Edition: 2012.12.01
The OUT_ORG_FINISH signal is turned ON after the power to an absolute motor is turned
ON even without performing a homing operation. This signal is not turned OFF until the power
is turned OFF regardless of servo ON/OFF. However, if a homing operation is performed, it is
turned OFF when starting a homing operation, and then turned ON when the homing
operation is complete.
(5) Setting the Current Position as the Position after a Homing Operation
Set parameter #57 [Coordinate value in command units after homing] to 0, and perform a
homing operation. Then, after moving the current position to the position desired after a
homing operation, set a home offset position. Do not set the coordinate system again while
performing a series of operations. For more information about the operation to set the home
offset position, see Section 6.4.11, "Command" and Section 8.4.2, "Terminal."
TIP