Electra Elite IPK II
Document Revision 4C
IP Trunk (SIP) – MG16
2 - 591
10-29-06
SIP Server Information Setup – Registrar IP Address
Define the Registrar IP Address. The carrier may provide an IP address. In most cases, a
domain name is used so this entry is left at the default.
0.0.0.0 ~ 126.255.255.254
128.0.0.1 ~ 191.255.255.254
192.0.0.1 ~ 223.225.255.254
(Default: 0.0.0.0)
10-29-07
SIP Server Information Setup – Registrar Port Number
Define the Registrar Port Number (0~65535).
(Default: 5060)
10-29-11
SIP Server Information Setup – Registrar Domain Name
Define the Registrar Domain Name (normally provided by the SIP carrier).
Example: [email protected]
Entries: 128 characters maximum
(Default: None)
10-29-15
SIP Server Information Setup – Registration Expiry (Expire) Time
Define the Registration Expire time – the time (120~65535 seconds) allowed to register with the
SIP carrier. This should stay at default.
(Default: 3600)
SIP Server Status
90-10-01
System Alarm Setup – Alarm Type
Defines alarm type 14 and 60.
Alarm 14 – CPU-LAN Link Error (IP Layer 1)
Assign a Major or Minor alarm status to for the LAN link. This program also assigns whether or
not the alarm is displayed to a key telephone and whether or not the alarm information is
reported to the predefined destination.
Alarm 60 – SIP Registration Error Notification
Assign a Major or Minor alarm status to for the SIP Registration Error. This program also assigns
whether or not the alarm is displayed to a key telephone and whether or not the alarm
information is reported to the predefined destination.
90-10-14
System Alarm Setup – CPUII-LAN Link Error (IP Layer 1)
Assign a Major or Minor Alarm status to for the LAN link. This program also assigns whether or
not the alarm is displayed to a key telephone and whether or not the alarm information is
reported to the predefined destination.
90-10-60
System Alarm Setup – SIP Registration Error Notification
Assign a Major or Minor Alarm status to for the SIP Registration Error. This program also
assigns whether or not the alarm is displayed to a key telephone and whether or not the alarm
information is reported to the predefined destination.
Summary of Contents for ELECTRA ELITE IPK II
Page 2: ......
Page 3: ...FEATURES AND SPECIFICATIONS MANUAL INT 1072 IPK II DOCUMENT REVISION 4C VERSION 2100 ...
Page 4: ......
Page 6: ......
Page 54: ...Document Revision 4C Electra Elite IPK II 2 30 Alarm THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 192: ...Document Revision 4C Electra Elite IPK II 2 168 Callback THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 206: ...Document Revision 4C Electra Elite IPK II 2 182 Caller ID THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 408: ...Document Revision 4C Electra Elite IPK II 2 384 Door Box THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 412: ...Document Revision 4C Electra Elite IPK II 2 388 Drop Key THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 544: ...Document Revision 4C Electra Elite IPK II 2 520 Intercom THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 549: ...Electra Elite IPK II Document Revision 4C Internal Hub 2 525 Operation None ...
Page 698: ...Document Revision 4C Electra Elite IPK II 2 674 K CCIS T1 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 714: ...Document Revision 4C Electra Elite IPK II 2 690 Long Conversation Cutoff ...
Page 730: ...Document Revision 4C Electra Elite IPK II 2 706 Memo Dial THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 784: ...Document Revision 4C Electra Elite IPK II 2 760 One Digit Dial Option Operation None ...
Page 810: ...Document Revision 4C Electra Elite IPK II 2 786 Park THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 1053: ...Electra Elite IPK II Document Revision 4C Uniform Numbering Network 2 1029 Operation None ...
Page 1189: ......
Page 1190: ...FEATURES AND SPECIFICATIONS MANUAL NEC Unified Solutions Inc Document Revision 4C ...