AKD PDMM User Guide | 39.28 MOTOR.TYPE
Description
This parameter is used to configure the motor temperature warning level as a resistance thresh-
old of the motor PTC.
A zero value prevents any warning from being created.
Related Topics
39.28 MOTOR.TYPE
General Information
Type
NV Parameter
Description
Units
N/A
Range
0, 1, 2 ,4
Default
Value
0
Data Type
Integer
See Also
N/A
Start Version M_01-00-00-000
Description
MOTOR.TYPE sets the drive control algorithms to different motor types as follows:
0 = Rotary motor
1 = Linear motor
2 = Induction Motor V/f Open Loop Control
4 = Induction Motor Closed Loop Control
The following table shows which MOTOR parameters must be configured for either permanent
magnet, induction motor v/f open loop, or induction motor closed loop motor types.
Keyword
Permanent
Magnet
Induction Motor v/f
Open Loop
Induction Motor
Closed Loop
Yes
Yes
Yes
MOTOR.TYPE
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Kollmorgen™ | December 2012
392
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...