AKD PDMM User Guide | 44.7 SM.V1
General Information
Default
Value
500 ms
Data Type
Integer
See Also
SM.I1, SM.I2, SM.MODE, SM.MOVE, SM.T1, SM.V1, SM.V2, SM.VPM1,
SM.VPM2
Start Ver-
sion
M_01-00-00-000
Description
SM.T2 defines the time of the service motion that is used in service motion modes 1, 3, and 5
(see SM.MODE).
Related Topics
44.7 SM.V1
General Information
Type
NV Parameter
Description Sets service motion velocity 1; active in opmode 1 (velocity) and 2 (position).
Units
Depends on or
Rotary: rpm, rps, deg/s, custom units/s, rad/s
Linear: Counts/s, mm/s, µm/s, custom units/s
Range
Rotary:
-15,000.000 to 15,000.000 rpm
-250.000 to 250.000 rps
-90,000.000 to 90,000.000 deg/s
-1,250.000 to 1,250.000 custom units/s
-1,570.796 to 1,570.796 rad/s
Linear:
-1,073,741,824,000.000 to 1,073,741,824,000.000 counts/s
-250.000*MOTOR.PITCH (pg 387) to 250.000*MOTOR.PITCH (pg 387) mm/s
-250,000.000*MOTOR.PITCH (pg 387) to 250,000.000*MOTOR.PITCH (pg
387) µm/s
-1,250.000 to 1,250.000 custom units/s
Default
Value
Rotary:
60.000 rpm
1.000 rps
359.999 deg/s
5.000 custom units/s
6.283 rad/s
Linear:
0.001 Counts/s
1.000*MOTOR.PITCH (pg 387) mm/s
999.998*MOTOR.PITCH (pg 387) µm/sec
5.000 custom units/s
435
Kollmorgen™ | December 2012
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...