AKD PDMM User Guide | 22.4 AOUT.OFFSET
-->AOUT.MODE 0
-->AOUT.VALUEU 5
-->AOUT.VALUEU 4.33
Related Topics
22.4 AOUT.OFFSET
General Information
Type
NV Parameter
Description
Sets the analog output off-
set.
Units
V
Range
-10 to +10 V
Default
Value
0 V
Data Type
Float
See Also
N/A
Start Version M_01-00-00-000
Fieldbus Information
Description
This parameter sets the analog output offset.
Related Topics
22.5 AOUT.PSCALE
General Information
Type
NV Parameter
Description
Sets the analog position scale factor.
Units
Rotary: counts/V,rad/V, deg/V, 16-bit
counts/V
Linear: counts/V, mm/V, µm/V, 16-bit
counts/V
Range
Rotary:
1 to 9,223,372,036,854,775 counts/V
0 to 13,493,026.816 rad/V
0 to 773,094,113.280 deg/V
0 to 140,737,488,355.327 16-bit counts/V
Linear:
1 to 9,223,372,036,854,775 counts/V
0 to 2,147,483.648 mm/V
0 to 2,147,483,648.000 µm/V
0 to 140,737,488,355.327 16-bit counts/V
214
Kollmorgen™ | December 2012
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...