AKD PDMM User Guide | 15.4 Parameter and Command Error Messages
Error Message
Meaning
Remedy
Occurrence
Error: Wrong argu-
ment for parameter
or command.
Argument was not
accepted.
Check the entered argument for accuracy.
Consult the reference guide or enter
DRV.LIST in the EWV terminal screen to
find valid parameter and command argu-
ments.
General.
Error: No arguments
allowed for param-
eter or command.
Parameter or com-
mand supports no
arguments.
Enter parameter or command again with no
arguments.
Commands and
read-only param-
eters
Error: Too many
arguments for
parameter or com-
mand.
Too many argu-
ments provided for
this parameter or
command.
Enter again with fewer arguments.
All parameters
and commands
with no or one
argument.
Error: No float
allowed.
Float number was
entered, but only
integer numbers are
allowed.
Enter integer value instead.
All parameters
and commands
with integer argu-
ments.
Error: Parameter or
command is read-
only.
Argument was not
accepted because
the parameter or
command is read-
only.
Enter again with no arguments.
Commands and
all read-only
parameters.
Error: Parameter is
temporarily write pro-
tected.
Argument was not
accepted because
the parameter is cur-
rently read-only.
Check reference guide or KAS IDE help to
determine if the parameter is read-only,
read-write, or nonvolatile.
Some param-
eters that come
from the Smart
Feedback Device
(SFD).
Error: Argument
greater than max-
imum value.
Entered argument
was beyond max-
imum value.
Enter a value that is within the allowable
range. See reference guide or KAS IDE
help for ranges.
Commands and
read-write param-
eters.
Error: Too many
characters in param-
eter or command.
Parameter or com-
mand string was
too long.
Shorten string and enter again.
General.
Error: Argument
less than minimum
value.
Entered argument
was too small.
Enter value that is within the limits.
Commands and
read-write param-
eters.
Error: Argument is
out of data range.
Entered argument
was not withing the
data range limits.
Enter value that is within the limits.
Commands and
read-write param-
eters.
Error: Parameter or
command is pass-
word protected.
Use of this param-
eter or command
requires a pass-
word.
Contact technical support to obtain pass-
word. Enter valid password.
Password pro-
tected param-
eters and
commands.
Error: Wrong oper-
ation mode for
parameter or com-
mand.
Requested param-
eter or command
cannot be per-
formed in this oper-
ation mode.
Change to valid operation mode.
Error: Drive ena-
bled. Disable drive
and continue.
Action can only be
performed if drive is
disabled.
Disable drive and repeat action.
Kollmorgen™ | December 2012
152
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...