AKD PDMM User Guide | 17.12.1 I/O Connectors X7 and X8 (all AKD PDMM variants)
Conn.
Pin
Signal
Abbreviation
Function
Wiring Diagram
X8
1
Fault Relay Output Fault Relay Output
Fault Relay Output
X8
2
Fault Relay Output Fault Relay Output
Fault Relay Output
X8
3
Digital Common X8
DCOM8
Common line for
X8 pins 4, 5, 6
X8
4
Digital Input 8
DIGITAL-IN 8
Output stage enable, not
programmable
X8
5
Digital Input 6
DIGITAL-IN 6
Programmable
X8
6
Digital Input 5
DIGITAL-IN 5
Programmable
X8
7
Analog Ground
AGND
Analog GND
X8
8
Analog
Analog-Out
Actual velocity voltage
X8
9
Analog Input -
Analog-In-
Velocity set point
X8
10
Analog Input +
Analog-In+
Digital common lines for X7 and X8 are not common to each other.
The DCOMx line should be connected to the 0V of the I/O supply when using sensors of type "Source"
with digital inputs.
The DCOMx line should be connected to the 24V of the I/O supply when using sensors of type "Sink" with
digital inputs.
Kollmorgen™ | December 2012
174
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...