AKD PDMM User Guide | 33.7 FBUS.STATE
33.7 FBUS.STATE
General Information
Type
R/O
Description
Reads the state of the fieldbus.
Units
N/A
Range
Depends on fieldbus. See table
below.
Default
Value
Depends on fieldbus. See table
below.
Data Type
Integer
Start Version M_01-08-00-000
Description
FBUS.STATE returns the current state of the fieldbus. The value returned is dependent upon
the fieldbus being used.
Value
CANopen over CAN
CANopen over EtherCAT
-1
Not connected
Not connected
0
Init.
-
1
N/A
Init.
2
N/A
Pre-operational
3
-
Boot
4
Stopped
Safe-operational
5
Operational
-
8
-
Operational
127
Pre-operational
-
33.8 FBUS.SYNCACT
General Information
Type
R/O Parameter
Description
Reads actual distance from the desired sync dis-
tance.
Units
ns
Range
0 to 250,000 ns
Default
Value
0 ns
Data Type
Integer, U 32
See Also
Appendix B: Fieldbus Manuals
Start Version M_01-00-00-000
Description
This parameter reads actual distance from the desired sync distance.
33.9 FBUS.SYNCDIST
General Information
Type
NV Parameter
338
Kollmorgen™ | December 2012
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...