AKD PDMM User Guide | 19.3 AKD PDMM Firmware Update
9. Click
Open
to start the updating procedure
This procedure is not possible when applications are running and when the drive
is in Online Configuration Mode.
During the firmware download, the AKD Firmware Update window displays a progress bar and the fol-
lowing messages are displayed:
l
Uploading firmware to the drive
During the download process, the drive LED displays [dL]. Additional codes may appear during the down-
load; see 3.2 Display Codes for a description of codes related to the firmware download.
l
Resetting the drive
l
Firmware update is complete
While the firmware is downloading to your drive, do not remove the 24V logic power. If
you remove the 24V logic power during a firmware download, a severe drive crash can
occur. If a crash occurs, the drive will restart in a special mode and prompt you to reload
the firmware.
190
Kollmorgen™ | December 2012
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...