AKD PDMM User Guide | 15.1 Fault and Warning Messages
Fault
Message/Warning
Cause
Remedy
n604 EMUEMODE incompatible
with DRV.HANDWHEELSRC.
Emulated encode mode is
incompatible with the selected
handwheel source.
Select a compatible emulated
encode mode or change hand-
wheel source.
F701
Fieldbus runtime.
Runtime communication fault. Check fieldbus connections
(X11), settings, and control unit.
F702
n702
Fieldbus communication lost.
All fieldbus communication
was lost.
Check fieldbus connections
(X11), settings, and control unit.
F703
Emergency timeout occurred
while axis should disable
Motor did not stop in the time-
out defined.
Change timeout value, change
stop parameters, improve tun-
ing.
Kollmorgen™ | December 2012