AKD PDMM User Guide | 8 Using AKD PDMM in a Vertical Axis
Vertical Appli-
cation Desired
Response
Customer Dis-
able Con-
dition
Configuration Needed
Parameter Settings Needed
Controlled stop
when possible. If
not possible,
apply motor
brake imme-
diately.
Normal dis-
able
Command CS using input. Do
not disable power stage or com-
mand other disables until CS
completes and brake applies.
DRV.DISMODE = 2. Controlled
stop then disable. Set:
DRV.DISTO , CS.VTHRESH ,
CS.DEC , CS.TO .
E-stop, or
safety con-
dition
Fault CS
Do not disable power stage or
command other disables until
CS completes and brake
applies.
Fault Dynamic
Brake
N/A
N/A
Fault Power
stage disable
None
MOTOR.BRAKEIMM = 1
Controlled stop
when possible. If
not possible,
dynamic brake.
Normal dis-
able
Command CS using input. Do
not disable power stage or com-
mand other disables until CS
completes and brake applies.
DRV.DISMODE = 3. Controlled
stop then disable. Set:
DRV.DISTO , CS.VTHRESH ,
CS.DEC , CS.TO .
E-stop, or
safety con-
dition
Fault CS
Do not disable power stage or
command other disables until
CS completes and brake
applies.
Fault Dynamic
Brake
N/A
N/A
Fault Power
stage disable
None
MOTOR.BRAKEIMM = 1
57
Kollmorgen™ | December 2012
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...