AKD PDMM User Guide | 39.31 MOTOR.VOLTMIN
General Information
Units
Vrms
Range
110 to 900 Vrms
Default
Value
230 Vrms
Data Type
Integer
See Also
N/A
Start Version M_01-00-00-000
Fieldbus
Index/Subindex Object Start Version
EtherCAT COE and CAN-
open
/0
M_01-00-00-000
Description
This parameter sets the maximum permissible motor voltage. For instance, if a motor that is
rated for a 400 V supply is connected to the drive, then the MOTOR.VOLTMAX setting is 400.
This value also sets regen resistor and over voltage thresholds in the drive to acceptable values
for the motor so that the motor windings are not damaged.
Related Topics
39.31 MOTOR.VOLTMIN
General Information
Type
NV Parameter
Description
Sets the minimum voltage for V/f control.
Units
%
Range
0 to 100%
Default
Value
2%
Data Type
U16
See Also
MOTOR.VRATED (pg 395), MOTOR.VOLTRATED (pg
395)
Start Version
Fieldbus
Index/Subindex Object Start Version
EtherCAT COE and CAN-
open
/3
M_01-00-00-000
Description
This parameter configures the drive for the induction motor's minimum voltage at standstill. It is
given as a percentage (%) of the motor’s rated voltage. MOTOR.VOLTMIN is used to calculate
the constant volts per Hertz characteristics of the drive and motor and should be set to a value
that generates a current of about 40% of the rated current at standstill.
Related Topics
Kollmorgen™ | December 2012
394
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...