AKD PDMM User Guide | 31.8 FB1.INITSIGNED
31.8 FB1.INITSIGNED
General Information
Type
NV Parameter
Description
Sets initial feedback value as signed or
unsigned.
Units
N/A
Range
0 to 1
Default
Value
1
Data Type
Integer
See Also
FB1.ORIGIN
Start Version M_01-00-00-000
Description
This parameter sets whether the initial value of the feedback read from the feedback device will
be set as a signed or as an unsigned value.
0 = Unsigned
1 = Signed
The drive internal process for the feedback initialization is as follows:
1. Reads the position feedback.
2. Adds the origin to the feedback.
3. Determines modulo from Step 2 by the actual feedback bits.
4. Sets the position feedback sign according to FB1.INITSIGNED.
Related Topics
31.9 FB1.MECHPOS
General Information
Type
R/O Parameter
Description
Reads the mechanical posi-
tion.
Units
counts
Range
0 to 4,294,967,295 counts
Default
Value
N/A
Data Type
Integer
See Also
N/A
Start Version M_01-00-00-000
Description
FB1.MECHPOS reads the mechanical angle which is equal to the lower 32 bits in the 64-bit
position feedback word.
Related Topics
313
Kollmorgen™ | December 2012
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...