AKD PDMM User Guide | 42.1 REGEN.POWER
42.1 REGEN.POWER
General Information
Type
R/O parameter
Description
Reads regen resistor's calculated
power.
Units
Watt
Range
N/A
Default
Value
N/A
Data Type
Integer
See Also
N/A
Start Version M_01-00-00-000
Fieldbus
Index/Subindex Object Start Version
EtherCAT COE and CAN-
open
/0
M_01-00-00-000
Description
This parameter reads regen resistor's calculated power, which is determined as follows:
(V
2
/ R) * DutyCycle
Related Topics
42.2 REGEN.POWERFILTERED
General Information
Type
R/O parameter
Description Returns a filtered version of REGEN.POWER .
Units
Watt
Range
0 to REGEN.WATTEXT
Default
Value
0
Data Type
Integer
Start Ver-
sion
M_01-07-01-000
Description
This parameter returns a filtered value of REGEN.POWER. A single order lowpass of
1/REGEN.TEXT Hz is applied to generate REGEN.POWERFILTERED.
If REGEN.POWERFILTERED exceeds the value of REGEN.WATTEXT, Fault 521 (Regen
overpower) will be generated.
This keyword may be recorded in the scope screen for analysis.
Example
REGEN.TEXT = 10 (seconds)
Lowpass Filter Frequence = 1/10 seconds = 0.1 Hz
REGEN.POWERFILTERED = REGEN.POWER * 0.1Hz lowpass
423
Kollmorgen™ | December 2012
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...