AKD PDMM User Guide | 25.4 CS.VTHRESH
25.4 CS.VTHRESH
General Information
Type
NV Parameter
Description Sets the velocity threshold for the controlled stop.
Units
rpm, rps, deg/s
Range
Rotary:
0.000 to 15,000.000 rpm
0.000 to 250.000 rps
0.000 to 90,000.000 deg/s
0.000 to 1,570.796 rad/s
Linear:
0.000 to 1,073,741,824,000.000 counts/s
0.000 to 8,000.000 mm/s
0.000 to 8,000,000.000 µm/s
Default
Value
5 rpm
Data Type
Float
See Also
CS.DEC (pg 237), CS.TO (pg 238), CS.STATE (pg 238), DRV.DIS (pg 272),
DIN1.MODE TO DIN24.MODE (pg 247),
DRV.DISMODE (pg 273), DRV.DISSOURCES (pg 274)
Start Ver-
sion
M_01-00-00-000
Fieldbus
Index/Subindex Object Start Version
EtherCAT and CAN-
open
M_01-00-00-000
Description
CS.VTHRESH is the velocity threshold for the controlled stop algorithm.
Example
Set velocity threshold for controlled stop at 100 rpm:
-->CS.VTHRESH 100
Related Topics
1 Digital Inputs and Outputs (Digital input mode 13)
Fault and Warning Messages (pg 135) (this table indicates faults for which a controlled stop
occurs)
Kollmorgen™ | December 2012
240
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...