Type
R/W Parameter
Description
Units
N/A
Range
0 to 24
Default
Value
0
Data Type
Integer
See Also
N/A
Start Version M_01-00-00-000
AKD SynqNet Information
Range
0
AKD BASIC Information
Range
0, 1, 13, 18, 19
Fieldbus
Index/Subindex
Object Start Ver-
sion
EtherCAT COE and CAN-
open
3562h/0 DIN1.MODE
M_01-00-00-000
3565h/0 DIN2.MODE
3568h/0 DIN3.MODE
356Bh
/0
DIN4.MODE
36F6h
/0
DIN5.MODE
36F9h
/0
DIN6.MODE
36FCh
/0
DIN7.MODE
60FDh
/0
DIN1.MODE TO
DIN7.MODE
Description
This parameter sets the functionality of the digital inputs 1 through 7. Digital inputs and cor-
responding X7 and X8 pin connectors are described in the
AKD PDMM Installation Manual
, sec-
tion 8.16.4, Digital Inputs. The table below summarizes the digital input modes; for detailed
descriptions of each mode, see Digital Inputs and Outputs (pg 1).
DINx.MODE
Description
Task
No function; off
0 - None
Fault reset
1 - Background
Start motion task (use
for this task)
2 - 1 KHz
Start jog
6 - Background
7
Reserved
7 - None
Zero latch
8 - Background
Command buffer
9 - Background
Kollmorgen™ | December 2012
247
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...