AKD PDMM User Guide | 48.12 VL.FBSOURCE
General Information
Range
N/A
Default
Value
N/A
Data Type
Float
See Also
Start Ver-
sion
M_01-00-00-000
Fieldbus
Index/Subindex Object Start Version
EtherCAT COE and CAN-
open
/1
M_01-00-00-000
Description
This parameter returns the same value as VL.FB (pg 457), filtered through a 10 Hz filter.
Related Topics
48.12 VL.FBSOURCE
General Information
Type
NV Parameter
Description
Sets feedback source for the velocity loop; active in opmodes 1 (velocity) and 2
(position) only.
Units
N/A
Range
0 to 1
Default
Value
0
Data Type
Integer
See Also
Start Ver-
sion
M_01-00-00-000
Description
This parameter determines the feedback source to be used by the velocity loop. A value of 0
selects the primary feedback, and 1 selects the secondary feedback.
Related Topics
48.13 VL.FBUNFILTERED
General Information
Type
R/O Parameter
Description
Reads the velocity feedback.
458
Kollmorgen™ | December 2012
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...