AKD PDMM User Guide | 48.16 VL.KBUSFF
General Information
Units
N/A
Range
0 to 1
Default
Value
0
Data Type
Integer
See Also
Start Ver-
sion
M_01-00-00-000
Description
This parameter is used to select the velocity generator mode.
Mode
Description
0
d/dt mode: The derivative of the mechanical angle of the drive is fed to a first order low
pass.
1
Luenberger Observer mode
Related Topics
48.16 VL.KBUSFF
General Information
Type
R/W Parameter
Description
Sets the velocity loop acceleration feedforward gain value; active in opmodes 1
(velocity) and 2 (position) only.
Units
NA
Range
0.0 to 2.0
Default
Value
0.0
Data Type
Float
See Also
Start Ver-
sion
M_01-00-00-000
Fieldbus
Index/Subindex Object Start Version
EtherCAT COE and CAN-
open
M_01-00-00-000
Description
This parameter sets the gain for the acceleration feedforward (a scaled second derivative of the
position command is added to the velocity command value).
The nominal feedforward value can be multiplied by this gain value.
This will have affect only when using position mode (DRV.OPMODE (pg 294) = 2).
Related Topics
460
Kollmorgen™ | December 2012
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...