AKD PDMM User Guide | 13.2.2.4 Trigger Value
In the EWV scope, the 0 time point is clear. When collecting the data via REC.RETRIEVE or similar com-
mands, the time is not returned, so some caution should be used when the trigger point is important to
understand.
Trigger position is not used in trigger type “Immediate” (TRIGTYPE 0).
13.2.2.4 Trigger Value
The trigger value (REC.TRIGVAL) specifies a target value that should trigger the recording to start. The
trigger value is used in trigger type Parameter / On Next Signal only.
The trigger value is not used in the boolean trigger type. Use the trigger slope to set the polarity of the bool-
ean trigger.
When the trigger slope is positive, the trigger value will trigger when:
l
The trigger source is less than the trigger value in the previous recording sample
l
The trigger source is greater than or equal to the trigger value in the current recording sample
Below is an example showing triggering of trigger value of 3 (REC.TRIGVAL 3) and positive trigger slope
(REC.TRIGSLOPE 1). You can see that the recording triggers at time zero when the source reaches the
value of 3.
Kollmorgen™ | December 2012
107
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...