AKD PDMM User Guide | 17.13 Analog Output (X8, X23)
17.13 Analog Output (X8, X23)
Analog Outputs can be used to output converted analog values of digital measurements recorded in the
drive. The standard drive offers one analog output on X8, drives with built-in I/O option card offer a second
output on X23. A list of the pre-programmed functions is included in the EWV
1
setup software.
Technical characteristics
l
Output voltage range referring to AGND: ±10 V
l
Resolution: 16 Bit and fully monotonic
l
Unadjusted offset: < 50 mV
l
Offset drift typ: 250 µV/°C
l
Gain or slope tolerance: +/- 3%
l
Nonlinearity: < 0.1% of full scale or 10 mV
l
Output impedance: 110 ohms
l
Specification complies with IEC 61131-2 Table 11
l
-3 dB Bandwidth: >8 kHz
l
Maximum output current: 20 mA
l
Capacitive load: any value but response speed limited by max Iout and by Rout
l
Protected for short circuit to AGND
Analog Output Wiring Diagram
1
Embedded Workbench Views
Kollmorgen™ | December 2012
178
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...