AKD PDMM User Guide | 39.18 MOTOR.PITCH
39.18 MOTOR.PITCH
General Information
Type
NV Parameter
Description
Units
µm
Range
1,000 to 1,000,000
µm
Default
Value
1.000 µm
Data Type
Integer
See Also
N/A
Start Version M_01-00-00-000
Description
This parameter defines the pole-to-pair pitch for the linear motor in micrometers.
Related Topics
39.19 MOTOR.POLES
General Information
Type
NV Parameter
Description
Sets the number of motor
poles.
Units
N/A
Range
0 to 128
Default
Value
6
Data Type
Integer
See Also
Start Version M_01-00-00-000
Fieldbus
Index/Subindex Object Start Version
EtherCAT COE and CAN-
open
/0
M_01-00-00-000
Description
MOTOR.POLES sets the number of motor poles. This command is used for commutation con-
trol and represents the number of individual magnetic poles of the motor (not pole pairs). The
division value of motor poles (MOTOR.POLES) and feedback poles (FB1.POLES) must be an
integer when setting drive to enable, otherwise a fault is issued.
Related Topics
387
Kollmorgen™ | December 2012
Summary of Contents for AKD PDMM series
Page 25: ...This page intentionally left blank 25 Kollmorgen December 2012...
Page 32: ...This page intentionally left blank 32 Kollmorgen December 2012...
Page 52: ...This page intentionally left blank 52 Kollmorgen December 2012...
Page 101: ...AKD PDMM User Guide 12 3 6 2 Biquad Calculations 101 Kollmorgen December 2012...
Page 133: ...This page intentionally left blank 133 Kollmorgen December 2012...
Page 158: ...AKD PDMM User Guide 17 Connection Diagrams Kollmorgen December 2012 158...
Page 470: ...AKD PDMM User Guide 48 27 VL THRESH 1 Velocity Loop 470 Kollmorgen December 2012...
Page 511: ...This page intentionally left blank 511 Kollmorgen December 2012...
Page 513: ...This page intentionally left blank 513 Kollmorgen December 2012...