Never use this machine in an environment with inflammable gas.
Avoid being hit by lightning. The power cable should be plugged into an outlet with grounding wire. Do not use
an outlet with poor condition. If possible, use power supply system with regulator.
It must be used in a clean environment protected against shock. Keep it away from corrosive substances,
explosive substances, high temperature and dampness.
If it is installed in a cabinet, make sure the installation allows for good ventilation, and easy maintenance,
observation and operation.
23.2 Disinfecting the Device and Accessories
Disinfection may cause damage to the device and is therefore not recommended for this monitor unless otherwise
indicated in your hospital’s servicing schedule. Cleaning device before disinfecting is recommended.
The recommended disinfects include:
75% Ethanol
70% Isopropanol
Do not use damaged accessories.
Accessories cannot be entirely immerged into water, liquor or cleanser.
Do not use radiation, steam or EO to disinfect accessories.
Do wipe off the remained Ethanol or isopropanol on the accessories after disinfection, for good maintenance can
extend the life of accessories.
Single-use accessories are not designed to be reused. Reuse may cause a risk of contamination and affect the
measurement accuracy.
Chapter 24 Maintenance
In case of trouble of this machine in the service, follow the instructions below to eliminate the problem first. If the
attempt fails, refer to the dealer in your local area or the manufacturer. Refer to the detailed provisions in contract for the
warranty period of the main unit and the accessories of this monitor.
24.1 Daily Examination
Before using the monitor, the checks below should be carried out:
Check the monitor for any mechanical damage;
Inspect the exposed parts and the inserted parts of all the cables and the accessories;
Examine all the functions of the monitor that are likely to be used for patient monitoring, and ensure that it is
in good working condition;
Make sure that the monitor is grounded properly.
Pay close attention to the fluctuation of the local power supply voltage. A power voltage regulator is
recommended when necessary.
In case any indication of damage about the function of the monitor is detected and proven, it is not allowed to apply it to
Summary of Contents for 35306
Page 2: ...2 ENGLISH Patient Monitor Operator s Manual ...
Page 21: ...21 ENGLISH Series III Front view Rear view Left view Right view 11 ...
Page 22: ...22 ENGLISH Series IV Front view Rear view Left view Right view 11 Extended Module ...
Page 171: ...2 ESPAÑOL Monitor de paciente Manual de operador ...
Page 343: ...2 FRANÇAIS Moniteur patient Manuel d utilisation ...
Page 362: ...21 FRANÇAIS Série III Vue de face Vue arrière Vue de gauche Vue de droite 11 ...
Page 519: ...2 ITALIANO Monitor Paziente Manuale d Uso ...
Page 538: ...21 ITALIANO Serie III Vista anteriore Vista posteriore Lato sinistro Lato destro 11 ...