Cascading
R&S
®
UPP
864
User Manual 1411.1055.32 ─ 10
8.6.1.1
GUI Control ALL
Selecting "All" makes it possible to apply the settings made for the master to all slaves.
This operating mode is recommended if the entire cascade is to behave like an instru-
ment with many channels.
Measurement result display
If a measurement has been started in this control mode, the measurement results of all
instruments in the cascade are displayed at the master.
Particularities:
Particularities concerning the configuration of a cascade in the ALL operating mode are
mentioned below.
Reference and trigger channel
In the cascade, the parameter fields "Ref Channel" and "Trigger Chan" in the Analyzer
Config panel have a special meaning.
"Ref Channel"
allows a reference channel for the phase measurement to be designa-
ted. If the phase measurement is to be performed across the entire cascade (see fig-
ure above), a "Ref Channel" must be defined in each instrument, preferably channel 1
(default).
"Trigger Chan"
specifies a trigger channel for deriving a trigger event for a measure-
ment. The channel determined as the trigger channel (channel 8 in the figure above)
Manual Operation of a Cascade
Содержание R&S UPP
Страница 1: ...R S UPP Audio Analyzer User Manual User Manual Version 10 1411105532 ÅP ...
Страница 34: ...Contents R S UPP 18 User Manual 1411 1055 32 10 ...
Страница 630: ...Instrument Functions R S UPP 614 User Manual 1411 1055 32 10 Format ...
Страница 631: ...Instrument Functions R S UPP 615 User Manual 1411 1055 32 10 Format ...