
Instrument Functions
R&S
®
UPP
377
User Manual 1411.1055.32 ─ 10
5.22.1
S/N Measurement Function
Measurement function for determining the signal to noise of a DUT.
Chapter 5.21, "Level Measurements"
Function (S/N)
Selection of S/N measurement.
Remote command:
SN
Meas Mode
Used for choosing the level weighting method for signal and noise measurement.
"RMS"
Both level measurements are carried out in the form of broadband
RMS measurements.
"Pos Peak"
Both level measurements are carried out in the form of peak value
measurements of the highest positive level.
"Neg Peak"
Both the level measurements are carried out in the form of peak
value measurements of the highest negative level
"Pk to Pk"
Both level measurements are carried out in the form of peak to peak
measurements
"Abs Peak"
Both the level measurements are carried out in the form of peak
value measurements of the absolute magnitude of the highest level.
Remote command:
DC Suppress
Used to activate DC suppression (in the digital analyzer only).
Signal-to-Noise Measurements
Содержание R&S UPP
Страница 1: ...R S UPP Audio Analyzer User Manual User Manual Version 10 1411105532 ÅP ...
Страница 34: ...Contents R S UPP 18 User Manual 1411 1055 32 10 ...
Страница 630: ...Instrument Functions R S UPP 614 User Manual 1411 1055 32 10 Format ...
Страница 631: ...Instrument Functions R S UPP 615 User Manual 1411 1055 32 10 Format ...