Instrument Functions
R&S
®
UPP
354
User Manual 1411.1055.32 ─ 10
event activates the continuous measurement (see
The R&S
UPP offers many different sweep options, which are briefly summarized
here:
●
Generator sweep system: Time-synchronous sweeps (DWELL sweeps) and ana-
lyzer-synchronous sweeps (AUTO sweeps) and manual sweeps (MANU sweeps).
They can also be 2-dimensional (provided that more than one sweepable parame-
ter exists for the selected generator function), i.e. 2 generator parameters are var-
ied. This is then referred to as a Z sweep because the z-axis is swept in addition to
the x-axis.
●
Analyzer sweep system: Analyzer-synchronous sweep of the RMS selection fre-
quency.
All sweeps can be performed either as parameter sweeps with constant increment or
as list sweeps.
5.20.2
Activating and Deactivating Sweeps
In the R&S
UPP the desired sweep system is activated or deactivated directly on the
associated function panel:
●
A generator sweep under "Sweep Ctrl" in the Generator
Function panel.
●
Sweep of the tracking filter for the "RMS Selective" measurement function under
"Sweep Ctrl" in the Analyzer
Function panel.
Only one of the two sweep systems can be active at any one time. If the user activates
a sweep while another sweep is already active, the sweep that is already active is
deactivated and a warning is issued. If an instrument or function which contains a
sweep is activated while another sweep is already active, the new sweep is deactiva-
ted and an appropriate warning is issued.
When a sweep is activated, the measurement system first continues to run in continu-
ous or single-measurement mode; the sweep system does not assume control of the
measurement system until the sweep is started.
When the active sweep is deactivated, the measurement system switches back to con-
tinuous measurement.
5.20.3
States of the Sweep System
The state of the sweep system is indicated above the 8th softkey.
Two-channel analyzer
Multichannel analyzer
Sweep Options
Содержание R&S UPP
Страница 1: ...R S UPP Audio Analyzer User Manual User Manual Version 10 1411105532 ÅP ...
Страница 34: ...Contents R S UPP 18 User Manual 1411 1055 32 10 ...
Страница 630: ...Instrument Functions R S UPP 614 User Manual 1411 1055 32 10 Format ...
Страница 631: ...Instrument Functions R S UPP 615 User Manual 1411 1055 32 10 Format ...