Remote Control - Command Description
R&S
®
UPP
737
User Manual 1411.1055.32 ─ 10
The return value comes in the basic unit (without engineering), e.g. a measurement
result of 1.2345 kHzis returned as 1234.5 (Hz), a measurement result of 12.345 µV as
12.345e-006 (V).
If the measurement result of an overranged channel is requested with the
SENSe<1|2|3|6>:DATA<n2>?
command, the value "3.40282038" (repre-
sents NaN = Not a Number) is returned.
Example
Display of channel 2’s current frequency measurement result in the numeric display.
Display of channel 2’s current frequency measurement result in the combined display
with minimum and maximum values.
Suffix:
<1|2|3|6>
.
selects the measurement to be read out,
1 = Function measurement result from column 1
6 = Level Monitor measurement result from column 2
2 = Input or Second-Monitor measurement result from column 3
3 = Frequency, Phase or Group Delay measurement result from
column 4
<n2>
1 | 2 | 3 …8
selects channel 1,2,3,…8.
Parameters:
<data>
float
Example:
Reads out the current frequency measurement result and the
respective
MIN
/
MAX
values from channel 2, see example above
for grahical respresentation:
SENS3:DATA2?
Response:
4823.6 Hz
SENS3:DATA2? MIN
Response:
1000 Hz
SENS3:DATA2? MAX
Response:
20000 Hz
Usage:
Query only
Triggering Measurements and Reading Results
Содержание R&S UPP
Страница 1: ...R S UPP Audio Analyzer User Manual User Manual Version 10 1411105532 ÅP ...
Страница 34: ...Contents R S UPP 18 User Manual 1411 1055 32 10 ...
Страница 630: ...Instrument Functions R S UPP 614 User Manual 1411 1055 32 10 Format ...
Страница 631: ...Instrument Functions R S UPP 615 User Manual 1411 1055 32 10 Format ...