Instrument Functions
R&S
®
UPP
611
User Manual 1411.1055.32 ─ 10
●
If Trace A and Trace B are both activated and the file to be imported contains only
one trace, and it does not matter whether it is Trace A or Trace B, this trace is
imported to Trace A
and
Trace B.
●
If only Trace A or only Trace B is activated and the file to be imported contains a
stereo trace, that is, Trace A and Trace B, the corresponding trace is imported,
namely A to A or B to B.
●
If Trace A and Trace B are both activated and the file to be imported contains a
stereo trace, then both traces are imported, namely A to A and B to B.
The following applies to all the cases listed:
All suitable scans from the file are appended. Starting from the first scan, all scans are
appended from the file until the maximum number of 20 scans is reached.
If "Hold" is selected in the parameter fields "Reference ", "Limit Upper " and "Limit
Lower ", the current settings are not changed by the imported scan.
5.53.1.10
Importing Scans from a File and Replacing an Existing Scan
parameter field "New Scan " = Replace
Parameter field "Alive/Hold" to Hold.
If the parameter field Alive/Hold is on "Alive" and a measurement is in progress (single
measurement not yet finished or continuous measurement), any attempt to import a file
is ignored and a message is issued.
If the parameter field "Alive/Hold" is on "Alive" and a measurement is finished, a scan
can be imported from a file and replace a scan.
If the default settings agree, it largely depends on the content of the import file whether
and how the operation proceeds.
A file will be imported only if the basic units from the file match the "Y-Source" setting,
or if the unit is allowed in the graphic subsystem. For example if "Y-Source " = Funct
Ch1 and the set analyzer measurement function = "RMS", a trace file with the basic
unit Volt is suitable. A trace file with the basic unit % would be ignored and an error
message would be issued.
When loading a trace file it must be clearly specified which trace is to be loaded from
the file (File:
Trace
A or File:
Trace
B).
This choice is not needed when importing. Provided the basic units are suitable for the
current setting, the file content defines what and how much will be imported:
●
If only Trace A or only Trace B is activated in "Y-Source" and the file to be imported
contains only one trace and it does not matter whether it is Trace A or Trace B,
then this trace is imported.
●
If Trace A and Trace B are both activated and the file to be imported contains only
one trace, and it does not matter whether it is Trace A or Trace B, this trace is
imported to Trace A
and
Trace B.
●
If only Trace A or only Trace B is activated and the file to be imported contains a
stereo trace, that is, Trace A and Trace B, the corresponding trace is imported,
namely A to A or B to B.
Load
Содержание R&S UPP
Страница 1: ...R S UPP Audio Analyzer User Manual User Manual Version 10 1411105532 ÅP ...
Страница 34: ...Contents R S UPP 18 User Manual 1411 1055 32 10 ...
Страница 630: ...Instrument Functions R S UPP 614 User Manual 1411 1055 32 10 Format ...
Страница 631: ...Instrument Functions R S UPP 615 User Manual 1411 1055 32 10 Format ...