Instrument Functions
R&S
®
UPP
510
User Manual 1411.1055.32 ─ 10
Available in the graphics subsystems
Sweep
If a Z sweep is set in the generator, Scan will automatically be set to Multi, provided
that X-Source = Sweep is set in the display panel.
Chapter 5.51, "Measured value Sequences"
"Single"
Only one trace (measurement sequence) or one trace pair (TRACE
A
and B) is to be recorded or loaded.
The display can be in the form of a trace or a bar graph.
The following parameter fields are hidden:
●
History
●
New Scan
●
Import From
If the "Show Min Max" checkbox is selected, two scans are added to
the single measurement sequence, and the toggle key [Next
Scan]
can be used to choose between three scans.
"Multi"
With this setting,
not just one
measurement sequence or pair of
measurement sequences (Trace
A and Trace
B) is recorded/loaded
and displayed but any number of sequences and sequence pairs.
However, only the number selected in the
History
parameter field is
stored internally and written to file or read from file; the maximum for
this number is 20. The scans that are not stored are only available in
the graphic and are lost if the graphical window is moved or resized, if
rescaling is performed, if trace files are stored/loaded or if setups are
stored/loaded.
The following parameter fields become available:
●
History
●
New Scan
●
Import From
Remote command:
Curve, Spectrum and Bar Graph Display
Содержание R&S UPP
Страница 1: ...R S UPP Audio Analyzer User Manual User Manual Version 10 1411105532 ÅP ...
Страница 34: ...Contents R S UPP 18 User Manual 1411 1055 32 10 ...
Страница 630: ...Instrument Functions R S UPP 614 User Manual 1411 1055 32 10 Format ...