Instrument Functions
R&S
®
UPP
525
User Manual 1411.1055.32 ─ 10
"Max "
The maximum Y value of the measurement sequence is actuated
once as the reference value. The display then returns to Value and
the maximum Y value is displayed as the new reference value in the
parameter field below.
"X-Cursor"
The Y value of the
*
Cursor is actuated once as the reference value.
The setting then returns to Value and the reference value is displayed
in the subsequent parameter field.
"O Cursor"
The Y value of the O Cursor is actuated once as the reference value.
The setting then returns to Value and the reference value is displayed
in the subsequent parameter field.
"Ref 997
Hz"
The Y value at 997
Hz is actuated once as the reference value. The
setting then returns to Value and the reference value is displayed in
the subsequent parameter field.
If the x-axis is not a frequency axis (e.g. in the case of level sweeps
or waveform displays), an error message is displayed and the refer-
ence value remains unchanged.
"Ref 1000
Hz" As for Ref 997 but with 1000
Hz
"Meas Ref Ch" This option is only available for multichannel instruments.
Every level measurement result of the channel specified in the Ana-
lyzer Config panel under Ref Channel
is saved as a reference value. If a referenced unit is selected in the
Unit parameter field, the measurement result is referenced to this
variable reference value and displayed.
"Meas Ch1"
Moving reference value
Every level measurement result for channel 1 is saved as reference
value and used as a referenced display, provided a reference unit
was selected. These options are only available for two-channel mea-
surement.
"Meas Ch2"
As for Meas Ch1 but with channel
2
"Gen Track"
The reference trace is deleted and the currently applicable generator
voltage, and then each newly set generator voltage, is used as the
reference value.
"File"
The reference trace is loaded from a file. The file name is entered in
the subsequent parameter field (see
on page 601). If Trace A is to be referenced, then the
Trace A from the specified reference file is used; if Trace B is to be
referenced, then Trace B is used. An error message occurs if the nec-
essary reference trace is not present in the file.
"File Intern"
"File Intern" has to be offered and displayed only if "File:Trace
A or
File:
Trace
B is set at "Y-Source" and a trace file containing a refer-
ence value scan in addition to the data scan is loaded.
Curve, Spectrum and Bar Graph Display
Содержание R&S UPP
Страница 1: ...R S UPP Audio Analyzer User Manual User Manual Version 10 1411105532 ÅP ...
Страница 34: ...Contents R S UPP 18 User Manual 1411 1055 32 10 ...
Страница 630: ...Instrument Functions R S UPP 614 User Manual 1411 1055 32 10 Format ...
Страница 631: ...Instrument Functions R S UPP 615 User Manual 1411 1055 32 10 Format ...