A-72
TROUBLESHOOTING
A
TROUBLESHOOTING
A-73
[22] Major hardware errors
22.40 : PCMCIA interface overtime
Code
: &H1628
Dedicated output
: *1
Meaning/Cause
Action
Failed to acquire access privilege for
PCMCIA interface.
1. Replace the PCMCIA interface driver.
2. Replace the controller.
22.41 : OPT.1 interface overtime
Code
: &H1629
Dedicated output
: *1
Meaning/Cause
Action
Failed to acquire access privilege for
interface with option board connected to
option slot 1.
1. Replace the option board connected
to option slot 1.
2. Replace the controller.
22.42 : OPT.2 interface overtime
Code
: &H162A
Dedicated output
: *1
Meaning/Cause
Action
Failed to acquire access privilege for
interface with option board connected to
option slot 2.
1. Replace the option board connected
to option slot 2.
2. Replace the controller.
22.43 : OPT.3 interface overtime
Code
: &H162B
Dedicated output
: *1
Meaning/Cause
Action
Failed to acquire access privilege for
interface with option board connected to
option slot 3.
1. Replace the option board connected
to option slot 3.
2. Replace the controller.
22.44 : OPT.4 interface overtime
Code
: &H162C
Dedicated output
: *1
Meaning/Cause
Action
Failed to acquire access privilege for
interface with option board connected to
option slot 4.
1. Replace the option board connected
to option slot 4.
2. Replace the controller.
Summary of Contents for RCX240
Page 1: ...RCX240 EUR6127206 E107 Ver 2 06 Userʼs Manual YAMAHA 4 AXIS ROBOT CONTROLLER ...
Page 2: ......
Page 18: ......
Page 34: ......
Page 78: ......
Page 402: ......
Page 448: ...5 46 Chapter 5 TWO ROBOT SETTING MEMO ...
Page 450: ......
Page 480: ...6 30 Chapter 6 PARALLEL I O INTERFACE MEMO ...
Page 482: ......
Page 494: ......
Page 506: ......
Page 512: ......
Page 522: ......
Page 611: ...INDEX ...
Page 612: ......
Page 617: ......
Page 619: ......