5-36
Chapter 5 TWO-ROBOT SETTING
4
1
2
3
5
6
7
8
9
10
Chapter 5 TWO-ROBOT SETTING
5-37
2.3.4
Setting the area check output
The area check output function performs area checks based on the robot's current position and the
point data area specified by the area check output parameters. The check result is then output to
the specified port.
n
NOTE
• For "Setting the area check output" details, also see "12.3.1 Setting the area
check output" in Chapter 4.
• The area check output function is disabled when in an "origin incomplete" status.
In the two-robot setting, the robot where the area check output is to be executed must be selected.
All other settings are identical to those used in the one-robot setting.
1
In the SYSTEM>OPTION>POS.OUT mode, use the cursor up/down (
/
) keys to select the area check output number, then press
(SELECT).
SYSTEM
>OPTION>POS.OUT V10.01
1.Output of area1 NO
2.Output of area2 NO
3.Output of area3 NO
4.Output of area4 NO
SELECT
Area check output (1) (controller prior to Ver. 10.10)
SYSTEM
>OPTION>POS.OUT V10.10
1.Output of area1 NO
2.Output of area2 NO
3.Output of area3 NO
4.Output of area4 NO
5.Output of area5 NO
SELECT
Area check output (1) (controller from Ver. 10.10 onwards)
2. Operations and data when using the two-robot setting
Summary of Contents for RCX240
Page 1: ...RCX240 EUR6127206 E107 Ver 2 06 Userʼs Manual YAMAHA 4 AXIS ROBOT CONTROLLER ...
Page 2: ......
Page 18: ......
Page 34: ......
Page 78: ......
Page 402: ......
Page 448: ...5 46 Chapter 5 TWO ROBOT SETTING MEMO ...
Page 450: ......
Page 480: ...6 30 Chapter 6 PARALLEL I O INTERFACE MEMO ...
Page 482: ......
Page 494: ......
Page 506: ......
Page 512: ......
Page 522: ......
Page 611: ...INDEX ...
Page 612: ......
Page 617: ......
Page 619: ......