4-320
Chapter 4 OPERATION
4
1
2
3
5
6
7
8
9
10
Chapter 4 OPERATION
4-321
14. "UTILITY" mode
14.6.1 Changing the access level
Change the access level as needed.
n
NOTE
The online command (@ACCESS) from the RS-232C allows changes to the access
level regardless of the password setting.
1
Press
(ACCESS) in "UTILITY" mode.
A message "Enter password" appears on the guideline.
2
Enter "LVL" here as the password and press
.
UTILITY
Date,Time : 08/06/20,18:59:37 ( 36°C)
Execut level: LEVEL7
Access level: LEVEL0
Enter password>LVL_
Setting the access level (1)
If the correct password was entered, the following screen appears.
UTILITY
>ACCESS
Access level: LEVEL0
LEVEL0 LEVEL1 LEVEL2 LEVEL3 HELP
Setting the access level (2)