4-254
Chapter 4 OPERATION
12. "SYSTEM" mode
Chapter 4 OPERATION
4-255
When the comparison points are set as shown below, and the robot axis tip is moved between
the marks, the output is off at
and the output is on at
. (when "5. Condition" is
set to "IN")
When points are designated in Cartesian coordinates ("mm" unit system)
Comparison point 2
+Z
+X
+Y
Comparison point 1
1
Press
(POS. OUT) in "SYSTEM>OPTION " mode.
The area check output mode is entered.
SYSTEM
>OPTION>POS.OUT V10.01
1.Output of area1 NO
2.Output of area2 NO
3.Output of area3 NO
4.Output of area4 NO
SELECT
Selecting the area check output number (controller prior to Ver. 10.10)
SYSTEM
>OPTION>POS.OUT V10.10
1.Output of area1 NO
2.Output of area2 NO
3.Output of area3 NO
4.Output of area4 NO
5.Output of area5 NO
SELECT
Selecting the area check output number (controller from Ver. 10.10 onwards)
2
Select an area check output number.
Use the cursor (
/
) keys to select the area check output number and
press
(SELECT).